(examples utilize and shows an 1.2GHz RF Module)
afterwards will be displayed the default Frequency of the RF Module setted in VFO_mode:
At successives startup will be displayed Mode and Frequency of the last utilize of module. Also RF device will be setted with these parameters.
Both into VFO and MEMORY mode the buttons (+) and (-) dispose of an
incremental speed to facilitate an easy setup of data.
Into VFO mode this increment will be actived after a countinouos
scan at least 5MHz from initial frequency.
Default Channel Memory will be the first, not
utilized, disponible. It's also possible to change it with (+) and (-)
into already used channels so to up to date relative memory's content.
The confirm of memorization will be activate by the pressure of P3.
A total of 48 MEMORY CHANNELS are availables.
in MEMORY_mode:
MEMORY > VFO
in this case will be reversed into VFO the Memory Frequency value
previous displayed in MEMORY mode.
START-UP FUNCTIONS
STEP
definible, with (+) and (-), in 125KHz steps into 125KHz÷1MHz range. Confirming
new value with P3.
OFFSET
definible, with (+) and (-), in 1MHz steps. Press at same time (+)
e (-) to define value's sign and if
it's to ADDING (+) or SUBTRACT (-) at the effective Vco's
Frequency.
To confirm new Offset press P3. Offset is useful when RF
Module is utilized as Local Oscillator of a Converter.
In this manner is Displayed the operative Frequency of Converter. Offset must be
setted at 0 into normal use of the RF-Module.
MULTIPLY
definible, with only use (loop) of (+) into the range 1÷24. Confirming the
Multiply pressing P3.
This parameter is useful when the armonics contents of a VCO are used to obtain
multiply of original and effective frequency or
rather into frequency
multiplyers. MULTIPLY setup influence only the displayed frequency value not the
Vco.
For a normal use
this parameter must be setted MULT=1.
Now the Setup
phases is terminated and we go back to the normal utilize of Display.